Useful in Preventing Cavitation Corrosion in high speed coolant pumps having aluminum housing and impellers. This could aid service life.

Product Description: 

COOLANT BESS GUARD is a high-performance, water-based liquid coolant formulated using high-purity water, polyols, advanced corrosion inhibitors, and special performance-enhancing additives.

It is specifically engineered for direct and indirect liquid cooling systems requiring high thermal efficiency, long-term material compatibility, and operational safety.

Coolant BESS Guard for Data Center is odorless, non-toxic, non-combustible, and environmentally safe. Its formulation provides excellent heat transfer efficiency, high thermal enthalpy, ultra-low freezing point, and stable fluid performance across a wide temperature range, making it ideal for modern data center and energy storage thermal management systems.

Product Application: 

Fields where Coolant BESS Guard Data Centers Battery Energy Storage Systems is used:

 

  • Data Center Cold Plate Liquid Cooling
  • Battery Energy Storage Systems (BESS)
  • Containerized Energy Storage Distribution Cabinets
  • New Energy Battery Panels
  • Intelligent Building & Base Cooling Systems
  • Hyperscale Data Centers
  • Edge Data Centers
  • EV Battery Cooling Panels
  • Smart Infrastructure Cooling
Product Procedure: 

Corrosion Protection Power of COOLANT BESS GUARD

Coolant BESS Guard - Battery Energy Storage System contains multi-functional, long-acting corrosion inhibitors that provide:
  • Passivation of metal surfaces
  • Protection against galvanic corrosion
  • Stability in mixed-metal systems
  • Reduced scale formation
  • Suitable for closed-loop and semi-closed loop cooling circuits.

Precursors to using Coolant BESS Guard

  • Designed for closed-loop liquid cooling systems
  • System should be clean and flushed before filling
  • Compatible with cold plate, immersion-adjacent, and hybrid cooling designs
  • Suitable for continuous operation and long service intervals
Product Note: 

Key Features of Coolant BESS Guard which boost Data Center performance

  • High heat exchange efficiency
  • High thermal enthalpy & latent heat capacity
  • Ultra-low freezing point
  • Excellent fluidity & low molecular weight
  • Non-flammable & non-explosive
  • No greenhouse effect
  • Long-term corrosion protection
  • Compatible with metals and non-metal materials
  • Stable performance under continuous circulation
Product Technical Specification: 
Property Typical Value Test Method
Appearance Clear, green liquid Visual
Odor Odorless Sensory
Density (25 °C) 1.05 – 1.15 g/cm³ ASTM D4052
pH (25 °C) 7.0 – 9.0 ASTM E70
Boiling Point ≥ 100 °C ASTM D1120
Thermal Conductivity Enhanced vs pure water ASTM D5470
Flash Point Non-flammable ASTM D92
Electrical Conductivity Low (controlled) ASTM D1125
Product pack size: 
COOLANT Corrosion inhibitor Concentrate
Product alias: 
<p> Data Center COOLANT, CXW-100 Cold Plate Coolant, Data Center Coolant Fluid</p>

Thermal Performance of Data Centers

  • High thermal enthalpy ensures rapid heat absorption
  • High latent heat of evaporation improves temperature stability
  • Low viscosity enables efficient circulation at low pumping energy
  • Excellent heat dissipation in high-density battery and CPU/GPU cold plates

 

Compatibility

Coolant BESS Guard is compatible with a wide range of materials commonly used in liquid cooling systems:
 
Metals
  • Copper & Copper Alloys
  • Aluminum & Aluminum Alloys
  • Carbon Steel
  • Stainless Steel
 
Non-Metals
  • EPDM, NBR, Silicone Rubber
  • Engineering Plastics (PVC, PP, PE, PTFE)
  • Elastomers used in seals and hoses
 
No swelling, cracking, or degradation under normal operating conditions.

Frequently Asked Questions

Q1. Why does RXSOL Coolant contain a RXSOL OxyShield Scavenger?

Answer: RXSOL Coolant contains a specialized oxygen scavenger to remove dissolved oxygen from the cooling system. Dissolved oxygen is one of the primary causes of internal corrosion in metal components such as copper, steel, and aluminum. By neutralizing free oxygen, the oxygen scavenger helps prevent rust formation, pitting, and oxidative degradation, ensuring longer equipment life, stable thermal performance, and reduced maintenance costs.
 
Q2. Why is a special compatible corrosion inhibitor added to RXSOL Coolant?
 
Answer: The corrosion inhibitor forms a protective molecular film on the internal surfaces of pipes, heat exchangers, cold plates, and metal components. This barrier prevents direct contact between the metal and corrosive elements such as water, oxygen, and dissolved salts. As a result, the coolant minimizes scale formation, galvanic corrosion between dissimilar metals, and material degradation, helping maintain efficient heat transfer and extending the operational lifespan of the cooling system. Not all inhibitors work in coolants and some may even cause further corrosion. Our experts have studied and formulated special corrosion inhibitors for coolants.
 
Q3. What is the role of RXSOL Color-Indicator in RXSOL Coolant?
 
Answer: The special color-indicators in RXSOL Coolant acts as a visual performance indicator. It helps operators quickly identify leaks, contamination, or dilution within the system. Over time, a noticeable change in color can signal that the coolant’s protective additives have been depleted or that the fluid has become contaminated. This allows for timely replacement or maintenance before system performance or equipment safety is compromised.

Various Grades of COOLANT is manufactured by RXSOL :::

Antifreeze Coolant Liquid Antifreeze compound for cooling water systems , It is a Very effective blend of GLYCOL classified chemicals along with CORROSION inhibitor to protects all engineering precious metal including aluminium . Its chemically treated layer protect radiators and RXSOL-16-4020-020
 
Coolant 20 Ltrs inhibitor concentrate/chemical which is added to the cooling water of internal combustion engines in cases in which the coolant does not need to be protected from freezing. It efforts excellent protection against cavitation and corrosion to all metals and RXSOL-40-4004-020
 
Coolant 25 Ltrs Useful in preventing cavitation corrosion in high speed coolant pumps having aluminum housing and impellers. This could aid service life. RXSOL-40-4004-025
 
Coolant 210 Ltrs inhibitor concentrate/chemical which is added to the cooling water of internal combustion engines in cases in which the coolant does not need to be protected from freezing. It efforts excellent protection against cavitation and corrosion to all metals and RXSOL-40-4004-210
 
Coolant Extended Life RXSOL ELC Especially useful in preventing cavitation corrosion in high speed coolant pumps having aluminum housing and impellers. This could aid service life. RXSOL-40-4016-025
 
Coolant Green RXSOL G 93-94 Inhibitor concentrate/chemical which is added to the cooling water of internal combustion engines in cases in which the coolant does not need to be protected from freezing. It efforts excellent protection against cavitation and corrosion to all metals and RXSOL-40-4021-025
 
Coolant Extended Life RXSOL ELC Suitable for high speed coolant pump, Especially useful in preventing cavitation corrosion in high speed coolant pumps having aluminum housing and impellers. This could aid service life. RXSOL-16-4016-210
 
Coolant 10 Ltrs inhibitor concentrate chemical which is added to the cooling water of internal combustion engines in cases in which the coolant does not need to be protected from freezing. It efforts excellent protection against cavitation and corrosion to all metals and RXSOL-40-4004-010
 
Coolant Green RXSOL G 93-94 inhibitor concentrate/chemical which is added to the cooling water of internal combustion engines in cases in which the coolant does not need to be protected from freezing. It efforts excellent protection against cavitation and corrosion to all metals and RXSOL-40-4021-020
 
Coolant Green RXSOL G 93-94 inhibitor concentrate/chemical which is added to the cooling water of internal combustion engines in cases in which the coolant does not need to be protected from freezing. It efforts excellent protection against cavitation and corrosion to all metals and RXSOL-40-4021-210
 
Coolant Premix Redcool premix coolant which reduces cavitation in areas such as the water pump and surface cavitation in hot spots of the cylinder head. The minimisation of cavitation erosion and pitting of heat rejecting aluminium surfaces (eg. behind exhaust ports) helps to i RXSOL-40-4043-025
 
Radiator Coolant 20% Conc. Suitable to add to the cooling water of internal combustion engines for excellent protection against cavitation and corrosion to all metals and alloys that are used in cooling systems.It is especially appropiate for the use in heavy-duty engines such as those used in trucks, ships and lokomotives. RXSOL-40-4045-025
 
Radiator Coolant 20% Conc. Suitable to add to the cooling water of internal combustion engines for excellent protection against cavitation and corrosion to all metals and alloys that are used in cooling systems.It is especially appropiate for the use in heavy-duty engines such as those used in trucks, ships and lokomotives. RXSOL-40-4045-210

COOLANT Manufcaturer and supplier in INDIA - UAE MIDDLE EAST GULF, OMAN, Nairobi Kenya, Sudan, Yemen. RXSOL COOLANT RXSOL-27-4004-025 exporter and supplier in Mumbai, Surat, Gandhidham, Kolkata, Chennai, Vizag Visakhapatnam, Paradip, Fujairah, Ajman, Abudhabi, Sharjah, Dubai, RUWI, Barka, Muscat, Sohar, Oman, Canada

Remarks: 
Key Features of Coolant Engine Guard
  • STRONG Antifreeze protection
  • Corrosion Protection for cast iron, steel, copper, brass, solder, and aluminum
  • Thermal Stability for high-temperature operations
  • Nitrite-based Inhibitor ensures long-term rust prevention
  • Low Foam, Low Toxicity compared to traditional inhibitors
  • Compatible with most sealants, elastomers, and metals