ROCCOR NB Corrosion Inhibitor

0
No votes yet
SKU::RXSOL-43-4001-030

Product Qty Per Unit: 
25.00
Product usage unit: 
Ltr.

Negotiate Price

Product Delivery Locations: 
Kandla, Gandhidham, Mundra, Sikka, Jamnagar, Surat, Navlakhi, Porbander, Pipava, Dehej, Hazira, Okha, Vadodra, Ahmedabad, Rajkot
Generic Name: 
Closed Cooling System corrosion inhibitor

Unique formulation with highly concentrated liquid cooling treatment compound, ferrous & Non ferrous corrosion inhibitors, antiscalants , dispersant and buffer solution of non carbonate.Usefull for use in high or low temperature closed cooling water syste

Product Description: 

COOLING WATER CORROSION & SCALE INHIBITOR
Corrosion Inhibitor for Water Systems  having  unique formulation with highly concentrated liquid cooling treatment compound, ferrous & Non ferrous corrosion inhibitors, antiscalants, dispersant and buffer solution of non carbonate. Usefull for use in high or low temperature closed cooling water systems for the prevention of corrosion and scale formation in internal combustion engines, compressors, chiller system and DG sets. Protects all metals including cast iron, mild steels and copper. Recommended ppm levels are easily controlled by standered RXSOL test kit Nitrite / Chloride.


The stable protective microfilm prevents corrosion caused by electrolytic action and the alkaline nature of this product prevents acid attack.

The stability of the added polymers are very useful for water treatment processes. Such polymers with low molecular weights cannot only inhibit calcium, magnesium, and silica scale in cooling towers and boilers, but also help corrosion control by dispersing iron oxide. 

Product Application: 

Prolongs the life of equipment by keeping it scale and corrosion free. Since RXSOL-40-4001-025 is alkaline, it will suppress acid corrosion, which would otherwise result in sever pittings. It improves cooling efficiency by maintaining clean heat transfer surfaces , from Radiators, DG - sets, Closed Cooling and chiller System.

FIELDS ::: --- Suitable for use in closed water cooling systems, ice melting systems and transformer cooling systems. The product may be used in all kinds of diesel & petrol engines, compressor or heating cooling water circuits.


( Used as a corrosion inhibitor for all ferrous and non-ferrous metals found in water systems )

Product Procedure: 

Refer to technical datasheet.

GENERAL RECOMMENDATION : ( The dosage chart may be used as a guide to adjust treatment to obtain the optimum level.)

Nitrite (as PPM NO2) 100-200 300-600 700-900 1100-1300   
RXSOL-40-4001-025 / 1000L 8.0  7.3 7-8 5-7   1.5-3.5

NOTE ::: --   If nitrite level becomes 1440-2400 then doses should be ZERO.

The initial dosage for an untreated system is 8 liters of product per 1000 liters of water. Such a dose will bring nitrite levels over 1200 ppm. Maximum nitrite level is considered to be 2400 ppm. Frequent tests should be carried out in order to maintain pH values within the limit (8.3-10.0), while levels of chloride should be maximum 50 ppm.
 

Product Note: 

Initial dosage for an untreated system is 9 litres of RXSOL-40-4001-025 / 1000 litres of untreated distilled water. This will bring the treatment up to the minimum level of 1000 ppm nitrite. For best result and prolonged engine life add RXSOL-40-4001-025 every 500 -6500 km. or 250 to 300 hours of running time or every 2 month interval. Specially designed for use in  water systems of internal combustion equipment. pH should be maintained between 8.3 and 10 by the treatment.

RXSOL-40-4001-025 will react with sludge and in most cases, facilitate sludge gradual removal. On badly fouled systems with oil or scale, a prior degreasing by using DEGREASER HEAVY DUTY or descaling by using DEGREASER HEAVY DUTY, SCALE REMOVER LIQUID or SCALE REMOVER POWDER is highly recommended.

• Excellent corrosion inhibitor for cooling water

• Minimises metal oxide deposits

• Protects ferrous and non-ferrous metals

• Compatible with glycol-based antifreeze

• Reduces cleaning & maintenance costs

• Cost effective, easy to apply and use

Product Technical Specification: 

RX MARINE INTERNATIONAL are continiously working in water treatement sector, And developed many unique product to avoid corrosion and scale depositon in cooling water system. Here I wants to keep our experiment results with you.Corrosion inhibitor for closed cooling systems containing molybdate/phosphonate ( RXSOL-40-4018-025 ). Sodium molybdate has the advantage in that the dosing of lower ppm's of molybdate allow for lower conductivity of the circulating water. Sodium molybdate at levels of 50-100 ppm offer the same levels of corrosion inhibition that sodium nitrite at levels of 800+ ppm. By utilizing lower concentrations of sodium molybdate, conductivity is kept at a minimum and thus galvanic corrosion potentials are decreased.

Product pack size: 
5, 20, 35, 50, 210 Ltr Mail us for Factory sale Discounted price of chemically effective corrosion inhibitor. Which is controlling common ferrous and non-ferrous metals in cooling water jacketed systems. Nitrite-borate based. Liquid and alkaline medium. Operates in a high and low-temperature closed system in internal combustion engines.
Product alias: 
<p> Caretreat 2 Diesel, Coronil 202, Gyrocor RX W.C., DEWT NC, Liquid EWT, Cool water Treat Corrosion Inhibitor, CWT Nclt diesel, Liquid guard 2000, ENGINE JACKET WATER CONDITIONER, Aquafine 103, CWT-NT Chemo, NCT-105 L Norc, Cooling Agent Liquid, Rocor NB Liquid 25 Ltr, Nalco 2000</p>
The closed cooling system uses the water flowing through a heat exchanger to remove heat from the engines. If Continuous flow of cooling water contains ROCCORRX Nb corrosion inhibitor and antifreeze mixture resulting good protect towards metal surface. 

CWT ROCCORRXRX NB Corrosion Scale Inhibitor Liquid is classified marine chemical corrosion inhibitor for engine cooling water systems. ROCCORRX NB Liq effectively protects ferrous and non-ferrous metals of engine cooling system. RXSOL CWT ROCCORRXRX NB Corrosion Scale Inhibitor Liquid is used in diesel engines, compressors, process cooling systems as ROCCOR nb liquid is the suitable and most popular corrosion inhibitor for closed heating or cooling systems of machinery and engine system.

CWT ROCCORRXRX NB Corrosion Scale Inhibitor Liquid  equivalent product is CWT Diessel NB Guard, Liqui dewt, ROCCORRX NB liquid
CWT ROCCORRX NB Corrosion Scale Inhibitor Liquid msds and technical bulletine available here.
CWT ROCCORRX NB Corrosion Scale Inhibitor Liquid is one of classified corrosion inihibitor for cooling water system. Ferrous and Non ferrous metal parts of cooling water system gets corrosion and changes into pitting formation which results in the form of leakage and many more. But presence of balance level of nitrite and borax which is main compenent of CWT ROCCORRX NB Corrosion Scale Inhibitor Liquid, effectively control corrosion on metal surface, This is the reason why uses of ROCCORRX NB liquid is most common in COOLING WATER SYSTEM on the other hand we can say that CWT ROCCORRX NB Corrosion Scale Inhibitor Liquid is the ideal corrosion inhibitor for closed heating or cooling systems, such as diesel engines, compressors, process cooling systems, etc.

Also refer this link http://rxmarine.com/engine-water-treatment-corrosion-inhibitor

CWT RoccorRX NB Corrosion Scale Inhibitor Liquid manufacturer and supplier in Mumbai, turbhe Pawana Navi Mumbai, Panvel, Taloja, Gandhidham, Kandla, Mundra, Jamnagar, Hazira, Surat, Manglore, Chennai Ennore, Visakhapatnam, Gangavaram, Kolkata, Haldia, Paradip Odisha, Fujairah, Dubai, Ajman, Abudhbai, Muscat Oman Barka Sohar, Canada

ROCCOR Nitrite Borax with proprietory mixture is most popular Corrosion Inhibitor for cooling water jacketed system.

How to Protect internal combustion engines, compressors, chiller system and DG sets from Corrosion?

ROCCOR NB Corrosion Inhibitor is a  unique formulation with highly concentrated liquid cooling treatment compound, ferrous & Non ferrous corrosion inhibitors, antiscalants, dispersant and buffer solution of non carbonate.

ROCCOR NB is specialized such a way which can be use in high or low temperature closed cooling water systems for the prevention of corrosion and scale formation in internal combustion engines, compressors, chiller system and DG sets. Also Usefull to Protects all metals including cast iron, mild steels and copper. Recommended ppm levels are easily controlled by standered RXSOL test kit Nitrite / Chloride.


The stable protective microfilm prevents corrosion caused by electrolytic action and the alkaline nature of this product prevents acid attack.

The stability of the added polymers are very useful for water treatment processes. Such polymers with low molecular weights cannot only inhibit calcium, magnesium, and silica scale in cooling towers and boilers, but also help corrosion control by dispersing iron oxide. 

During Circulation of water mainly controlling of 2 factors required : -
 
SCALE CONTROL in closed water cooling systems - Diesel and gas engines releasing high temperature due to that water present in jacket cooling system  increases its tendency to deposit scale. To avoid scale formation water softener like Zeolite  gradual buildup of scale in cylinders and cylinder heads. Where condensate is available, it is preferred for closed system cooling water makeup. Where condensate is not available, zeolite softening should be applied to the makeup water.
 
CORROSION CONTROL An increase in water temperature causes an increase in corrosion. At high temperature  solubility of oxygen in water decreases due to that Corrosion rates increasing inside the system.  This occurs because the lower solubility of oxygen with increasing temperatures in a freely vented system decreases the corrosion rate faster than the rise in temperature increases it. However, in many closed systems, the dissolved oxygen entering the system in the makeup water cannot be freely vented, resulting in the release of oxygen at points of high heat transfer, which may cause severe corrosion. Untreated systems can suffer serious corrosion damage from oxygen pitting, galvanic action, and crevice attack. Closed cooling systems that are shut down periodically are subjected to water temperatures that may vary from ambient to 180°F (82°C) or higher. During shutdown, oxygen can enter the water until its saturation limit is reached. When the system is returned to high-temperature operation, oxygen solubility drops and the released oxygen attacks metal surfaces. 
 
The three most reliable corrosion inhibitors for closed cooling water systems are chromate, molybdate, and nitrite materials. Generally, the chromate or molybdate types have proven to be superior treatments.
ROCCOR NB Corrosion Inhibitor

What is closed cooling system ?

The full closed cooling system is designed to circulate cooling water through the block and exhaust manifold.  water is circulated through water pump to heat exchanger tank and be pumped through many small tubes where it will exchange heat from the water of the circulating system. Then water exits the heat exchanger to go directly into the risers and then exit the boat. The exhaust manifold and riser will be blocked off, so no water will transfer between them. As for the circulating water in the closed cooling system, cool water will enter the engine through the circulating pump and circulate through the engine. The water will heat up in the engine and the warm water will exit at the water outlet on top of the manifold and head to the manifolds. After circulating through the manifolds, the hot water will head to the heat exchanger to exchange the heat it's carrying with the raw water. After the exchange the cool circulating water exits the heat exchanger and returns to circulating pump to begin another loop. 
 

How to Protect internal combustion engines, compressors, chiller system and DG sets from Corrosion?
 
ROCCOR NB Corrosion Inhibitor is a  unique formulation with highly concentrated liquid cooling treatment compound, ferrous & Non ferrous corrosion inhibitors, antiscalants, dispersant and buffer solution of non carbonate.
 
ROCCOR NB is specialized such a way which can be use in high or low temperature closed cooling water systems for the prevention of corrosion and scale formation in internal combustion engines, compressors, chiller system and DG sets. Also Usefull to Protects all metals including cast iron, mild steels and copper. Recommended ppm levels are easily controlled by standered RXSOL test kit Nitrite / Chloride.
 
 
The stable protective microfilm prevents corrosion caused by electrolytic action and the alkaline nature of this product prevents acid attack.
 
The stability of the added polymers are very useful for water treatment processes. Such polymers with low molecular weights cannot only inhibit calcium, magnesium, and silica scale in cooling towers and boilers, but also help corrosion control by dispersing iron oxide. 
 
FIELDS ::: --- Suitable for use in closed water cooling systems, ice melting systems and transformer cooling systems. The product may be used in all kinds of diesel & petrol engines, compressor or heating cooling water circuits.
 
 
 
Where Roccor NB can be used?
 
Prolongs the life of equipment by keeping it scale and corrosion free. Since RXSOL-40-4001-025 is alkaline, it will suppress acid corrosion, which would otherwise result in sever pittings. It improves cooling efficiency by maintaining clean heat transfer surfaces , from Radiators, DG - sets, Closed Cooling and chiller System.
 
FIELDS ::: --- Suitable for use in closed water cooling systems, ice melting systems and transformer cooling systems. The product may be used in all kinds of diesel & petrol engines, compressor or heating cooling water circuits.
 
 
( Used as a corrosion inhibitor for all ferrous and non-ferrous metals found in water systems )
 
 
 
DOSES and Using procedure of ROCCOR NB?
 
 
GENERAL RECOMMENDATION : ( The dosage chart may be used as a guide to adjust treatment to obtain the optimum level.)
 
Nitrite (as PPM NO2) 0 100-200 300-600 700-900 1100-1300   
RXSOL-40-4001-025 / 1000L 8.0 7.3 7-8 5-7  1.5-3.5
NOTE ::: --   If nitrite level becomes 1440-2400 then doses should be ZERO.
 
 
The initial dosage for an untreated system is 8 liters of product per 1000 liters of water. Such a dose will bring nitrite levels over 1200 ppm. Maximum nitrite level is considered to be 2400 ppm. Frequent tests should be carried out in order to maintain pH values within the limit (8.3-10.0), while levels of chloride should be maximum 50 ppm.
 
Initial dosage for an untreated system is 9 litres of RXSOL-40-4001-025 / 1000 litres of untreated distilled water. This will bring the treatment up to the minimum level of 1000 ppm nitrite. For best result and prolonged engine life add RXSOL-40-4001-025 every 500 -6500 km. or 250 to 300 hours of running time or every 2 month interval. Specially designed for use in  water systems of internal combustion equipment. pH should be maintained between 8.3 and 10 by the treatment.
 
RXSOL-40-4001-025 will react with sludge and in most cases, facilitate sludge gradual removal. On badly fouled systems with oil or scale, a prior degreasing by using DEGREASER HEAVY DUTY or descaling by using DEGREASER HEAVY DUTY, SCALE REMOVER LIQUID or SCALE REMOVER POWDER is highly recommended.
 
 
• Excellent corrosion inhibitor for cooling water
 
• Minimises metal oxide deposits
 
• Protects ferrous and non-ferrous metals
 
• Compatible with glycol-based antifreeze
 
• Reduces cleaning & maintenance costs
 
• Cost effective, easy to apply and use

ROCCOR NB Corrosion Scale Inhibitor Liquid specialized marine chemical product for Cooling Water treatment. ROCCOR NB Corrosion Scale Inhibitor Liquid supplier in Mumbai, Kandla Mundra, TURBHA MIDC NAVI Mumbai, Hazira SURAT, Visakhapatnam, Gangavaram, Chennai, Ennore, Kolkata, Haldia, Paradip, Kakinada, Fujairah, Ajman, Abudhabi, Sharjah, Dubai, UAE GULF, Ruwi Gala Barka, Muscat Oman, Canada, Nairobi Kenya Sudan, Yemen
Remarks: 

Before testing of Nitrite level, Here is some point and guideline,  what you need to do. : 1 take the following readings; pH, TDS (uS), and nitrite level.and record. 2 add the Chemical your are using. 3. wait for a period of time for the sysem to circulate. hours> 4. Re check the readings. and record. 5 track these readings
for a period of time.

If the TDS and Nitrite drop you have a leak/ unknown makeup. if the TDS stays stable and the nitrite drops you have a biological problem. Bacteria that convert nitrite to nitrate.

Solution ::: Use DI water in place of general water, And also use. Algaecide to control Bacterial growth inside water system ... http://rxmarine.com/Biocide-Algaecide