Skip to main content
Home / Products / Detergent & Soap-12 / HCF Cleaner

HCF Cleaner

HCF Cleaner
Detergent & Soap-12
Product code  RXSOL-20-2007-025

Especially formulated to soften up / remove baked on drying oils and also used after animal and vegetable oils, fish oils, tall oils,tug oil etc. It is low toxic product with an exceptional solvency power on soil & oily matter .It is free from hydroc

Supply to Kandla, Mundra & Sikka ports Bulk & custom packaging Technical support included

Product Description

Product Description

RXSOL HCF Remover is a heavy-duty, low-foaming marine tank cleaning chemical specially developed for removing hydrocarbon residues, baked-on drying oils, animal and vegetable oils, fish oils, grease, wax, sludge and other stubborn organic deposits.

Its blend of surfactants, wetting agents and cleaning solvents helps penetrate and loosen difficult residues, allowing effective removal through tank cleaning machines, circulation systems and spray washing.

The product is particularly useful when preparing cargo tanks for subsequent cargoes where residual hydrocarbon contamination must be minimized.

Specially formulated to soften up / remove baked-on drying oils and also used after the animal and vegetable oils, fish oils, tall oils, tung oil etc. It is a low toxic product with an exceptional solvency power on soil & oily matter.It is free from hydrocarbon solvents and minimizes the extreme hazards to personnel in handling materials.
RXSOL-20-2007-025 is a very strong low foaming multipurpose cleaner.

Application & Usage

Applications

  • Cargo tank cleaning after petroleum and chemical cargoes.

  • Removal of animal oils, vegetable oils, fish oils and tall oil residues.

  • Cleaning tanks contaminated with grease, wax and oily sludge.

  • Removal of soot, carbon deposits and general grime.

  • Cleaning of stainless steel and compatible coated cargo tanks.

  • Final cleaning stages before hydrocarbon-sensitive cargoes.

First of all flush the system with water to stop evaporation rates and polymerization effect of oil, then can be adopt most economical method of using RXSOL-20-2007-025 is by direct injection followed by recirculation washing, using tank cleaning machines.

Dosage

Recommended Cleaning Procedure

1. Initial Washing: Flush cargo tanks with cold water to remove loose residues and reduce the risk of polymerization of drying oils.

2. Chemical Cleaning: Prepare an appropriate dilution of RXSOL HCF Remover according to the cargo residue, tank coating and approved cleaning procedure.

3. Recirculation: Circulate through tank cleaning machines, ensuring suitable filtration or straining.

4. Spot Cleaning: For persistent residues, apply the cleaner directly and allow approximately 10–45 minutes of contact without letting it dry.

5. Final Rinsing: Wash thoroughly with fresh water, inspect the tank and confirm that residues and foam have been removed.

The published application instructions also describe warm-water washing at approximately 60°C for suitable systems. Temperature limits must be checked against tank coating specifications.

RXSOL TANK CLEANER

Using-Procedure:-First of all flush the system with cold water to prevent evaporation rates and polymerization then the most economical method of using RXSOL-20-2007-025  is by direct injection followed by recirculation washing, using tank cleaning machines.

Spraying Method:-Using HCF as delivered in drums, spray onto areas where residue remains following rough washing leave for 10-45 minutes (but do not allow to dry), then butterworth at maximum pressure and warm water 60oC for at least 3 hours, checking that there is no foam remaining in the final stages.  Inspects tanks(s) and if desired result has been achieved fresh water rinse and dry.

** Make sure to take all safety precautions are followed when handling / spraying HCF **

Injection Method:– Not applicable.

Re-circulation Method:–Fill tank with fresh water and heat up to warm 50oC .  IF a drop line is available on the tank line system, then start to circulate the water and add the required amount of Caustic flakes and HCF to make a 2.5% solution.  A stronger solution can be made, but be advised that too much Caustic and too high temperature will result in white powder all over the tank.  Under normal circumstances, between 2.5% and 4.5% will be sufficient strength.  If there is no drop line, then lower Butterworth hoses into the tank from the pump stack header without machines attached and circulate through these hoses while you fill the solution material. 

**Use a strainer at the pump stack when circulating any solution.** 

Useful Area

FAQs — Hydrocarbon Remover HCF Remover

1) What is Hydrocarbon Remover used for?

A powerful, low-foaming cleaner formulated to soften and remove baked-on drying oils. Ideal for cleaning after handling animal and vegetable oils, fish oils, tall oils, tung oil, and similar residues.

2) Is it safe for personnel?

Yes. It is low in toxicity, free from hydrocarbon solvents, and minimizes hazards during handling. Standard PPE such as gloves and goggles is still recommended.

3) How effective is it on stubborn residues?

It has exceptional solvency power on soils and oily matter, making it effective even on hardened or baked-on deposits.

4) Is it suitable for all industries?

Yes. While widely used in marine cleaning, it is also effective in food processing, oil handling, and industrial maintenance where oils and greasy residues are present.

5) Does it contain hydrocarbon solvents?

No. It is completely free from hydrocarbon solvents, making it safer for the environment and personnel.

Industrial Area

Key Features

  • Strong oil and grease removal.

  • Low-foaming formulation for recirculation systems.

  • Water-based cleaning chemistry.

  • Miscible with fresh water and seawater.

  • Helps suspend loosened contaminants to reduce redeposition.

  • Suitable for selected epoxy, phenolic and zinc-silicate tank coatings, subject to coating approval.

 

We are classified as Marine Chemical Products and Tank Cleaning Chemicals supplier. We cover the full range of Marine Cleaning Chemicals which is Heavy Duty and economical to use. We are keeping ready stock of  Industrial Chemical Products, marine cleaning maintenance Chemicals, Boiler water treatment Chemicals, Cooling Water Treatment Chemicals, Fuel Oil treatment, Deck Cleaning Items, Oil Spill Dispersant, Tank Cleaner, Tank Clean, Rig wash, Carbon Remover, Deck Cleaner, Teak Renewer, Epoxy paint Solvented, water free hand cleaner, water free hand wash, biological toilet cleaner, all pupose cleaner, Oil Spill Dispersant, OSD Type I II, Heavy Duty Degreaser, Rigwash, Aqua Break, Sea-cleaner Plus, Alkaline Safety liquid etc at all INDIAN coastal and in Middle East.

Technical Specifications

Typical Technical Properties

Parameter

Published / Indicative Value

Appearance

Clear to yellowish liquid

pH

Above 7

Specific Gravity at 20°C

Approx. 1.01

Water Miscibility

Fully miscible

Foaming

Low

Cleaning Chemistry

Non-ionic surfactants and glycol ethers

 

RXSOL – Manufacturer & Supplier of Tank Cleaner

Remarks / Precautions

Characteristics: -

  • Removes grease, oil, carbon deposits, soil and grime.
  • Keeps loosened deposits in suspension preventing re-deposition.
  • Low toxic.  , Non-flammable.
  • Free from hydrocarbon solvents.
  • Effective and economical in use , Water-based cleaner.
  • RXSOL-20-2007-025 has numerous cleaning applications including removal of greases, waxes, oil, sludge, soot, carbon deposits and general dirt and grime.
  • Non-corrosive to ferrous metals.  Suitable for all tank-coatings.
  • Can be used for gas and hydrocarbon freeing of tanks.
  • Can be used for deodorizing
  • Contains wetting agents.

Note:- Completely miscible with sea water.

Procedure

Recommended Cleaning Procedure

1. Initial Washing: Flush cargo tanks with cold water to remove loose residues and reduce the risk of polymerization of drying oils.

2. Chemical Cleaning: Prepare an appropriate dilution of RXSOL HCF Remover according to the cargo residue, tank coating and approved cleaning procedure.

3. Recirculation: Circulate through tank cleaning machines, ensuring suitable filtration or straining.

4. Spot Cleaning: For persistent residues, apply the cleaner directly and allow approximately 10–45 minutes of contact without letting it dry.

5. Final Rinsing: Wash thoroughly with fresh water, inspect the tank and confirm that residues and foam have been removed.

The published application instructions also describe warm-water washing at approximately 60°C for suitable systems. Temperature limits must be checked against tank coating specifications.

RXSOL TANK CLEANER

Using-Procedure:-First of all flush the system with cold water to prevent evaporation rates and polymerization then the most economical method of using RXSOL-20-2007-025  is by direct injection followed by recirculation washing, using tank cleaning machines.

Spraying Method:-Using HCF as delivered in drums, spray onto areas where residue remains following rough washing leave for 10-45 minutes (but do not allow to dry), then butterworth at maximum pressure and warm water 60oC for at least 3 hours, checking that there is no foam remaining in the final stages.  Inspects tanks(s) and if desired result has been achieved fresh water rinse and dry.

** Make sure to take all safety precautions are followed when handling / spraying HCF **

Injection Method:– Not applicable.

Re-circulation Method:–Fill tank with fresh water and heat up to warm 50oC .  IF a drop line is available on the tank line system, then start to circulate the water and add the required amount of Caustic flakes and HCF to make a 2.5% solution.  A stronger solution can be made, but be advised that too much Caustic and too high temperature will result in white powder all over the tank.  Under normal circumstances, between 2.5% and 4.5% will be sufficient strength.  If there is no drop line, then lower Butterworth hoses into the tank from the pump stack header without machines attached and circulate through these hoses while you fill the solution material. 

**Use a strainer at the pump stack when circulating any solution.** 

Tag Identification

Neutral HCF is free from solvents to clean Vegetable, Animal oil etc from Ship and marine Tanks. Excellent neutral tank cleaner cum degreaser. This product is most popular among tanker operating charter and shipping agent.

RXSOL HCF REMOVER

Hydrocarbon-Free Tank Cleaning Chemical | Marine & Industrial Degreaser

Product Name: HCF Remover Neutral

Product Code: RXSOL-20-2007-020

Brand: RXSOL

Category: Marine Tank Cleaning Chemicals

Type: Water-based, low-foaming detergent and degreaser

Product details verified against published RXSOL listings.

 

RXSOL – Manufacturer & Supplier of Hydrocarbon-Free Tank Cleaning Chemical | Marine & Industrial Degreaser

Notes

COLD water is recommended for drying or semi-drying oils  to flush the tank as prewash. Chemical expert suggest that cold water should be carried out immediately after discharge of cargo to prevent hardening of oil residues. Otherwise if oil is nondrying then Prewash of the tank with hot water at 50˚C is good decision to achieve BEST cleaning result.  
Tank Lining– Stainless / Epoxy / Phenolic / Zinc-silicate coatings and from most metal surfaces (ferrous alloys, tin, zinc, aluminium and galvanized surfaces).

Other Names

HCF Neutral, Hydrocarbon Remover, MAC-hc-100, Careclean Neutral HCF, MarClen Green 25 Ltr

Packing Sizes

20, 25, 50, 210, 1000 Ltr IBC TANK. Feel free to mail us for factory discounted price. STOCK available at Mumbai, Kandla, Surat, Goa, Tuticorin, Visakhapatnam, Gangavaram, Ennore, Chennai, Kolkata, Haldia, Fujairah - Dubai, Middle East

Material Safety Data Sheet (MSDS)

Heading1 - West India Chemical

Product Name RXSOL-20-2007-025
Product Type HCF REMOVER-II

 Company Details:

RX MARINE INTERNATIONAL 105, A wing , BSEL , TECH PARK. VASHI ,NEW BOMBAY 400703 INDIA

Phone +91 22 65113333 / 5555 / 9999 / 27611360
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email mail @ rxmarine.com

Heading2 - West India Chemical

* Chemical characterization
* Description:    Mixture of the substances listed below with harmless additions.
* Dangerous components:
  CAS        : 111-76-2      2-butoxyethanol    Xn; R 20/21/22-36/38    5-10%
  EINECS  : 203-905-0
                 Alco     Xi; R 38            7.0%
  CAS        : 112-34-5    2-(2-butoxyethoxy)ethanol    Xi; R 36    2.5-5%
  EINECS  : 203-961-6

*See Section 16

Heading3 - West India Chemical

Chemical characterization

Description

Mixture of substances listed below with nonhazardous additions. Cleansing agent

Dangerous components 

non-ionic surfactants Xn, Xi; R 22-41 10-25 % CAS: 111-76-2

Einecs

203-905-0 2-butoxyethanol Xn, Xi; R 20/21/22-36/38 2.5-10%

Heading4 - West India Chemical

General Information

Immediately remove any clothing soiled by the product. Symptoms of poisoning may even occur after several hours; therefore medical observation for at least 48 hours after the accident.

After inhalation

Supply fresh air; consult doctor in case of complaints.

After skin contact

Generally the product does not irritate the skin.

After eye contact

Rinse opened eye for several minutes under running water. Then consult a doctor.

After swallowing

Call for a doctor immediately

Heading5 - West India Chemical

Suitable extinguishing agents

CO2, powder or water spray. Fight larger fires with water spray or alcohol resistant foam.

Protective equipment

No special measures required.

Heading6 - West India Chemical

Person-related safety precautions

Wear protective clothing.

Measures for environmental protectio

Dilute with plenty of water.

 

Do not allow to enter sewers/ surface or ground water.

Measures for cleaning/collecting

Absorb with liquid-binding material (sand, diatomite, acid binders, universal binders, sawdust).Dispose contaminated material as waste according to item 13.Ensure adequate ventilation.Dispose Of The Material Collected According To Regulations.

Heading7 - West India Chemical

Handling

Information for safe handling

Store in cool, dry place in tightly closed receptacles..Prevent formation of aerosols.

Information about fire- and explosion protection

No special measures required.

Storage

Requirements to be met by storerooms and receptacles

No special requirements.

Information about storage in one common storage facility

Not required.

Further information about storage conditions

None.

Heading8 - West India Chemical

Additional information about design of technical facilities: No further data; see item 7. • Ingredients with limit values that require monitoring at the workplace: 111-76-2 2-butoxyethanol WEL    Short-term value: 50 ppm Long-term value            : 25 ppm • Additional information : The lists valid during the making were used as basis. • Personal protective equipment: • General protective and hygienic measures: Keep away from foodstuffs, beverages and feed. • Respiratory protection : Not required. • Protection of hands     : Protective gloves The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. • Material of gloves The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and varies from manufacturer to manufacturer. • Penetration time of glove material The exact break trough time has to be found out by the manufacturer of the protective gloves and has to be observed. • Eye protection   : Safety glasses • Body protection : Protective work clothing

Heading9 - West India Chemical

General Information

Form

Fluid

Colour 

Yellowise / Clear

Odour

Characteristic

• Change in condition

Melting point/Melting range

Undetermined.

Boiling point/Boiling range

171°C

• Ignition temperature

240°C

• Self-igniting

Product is not selfigniting.

• Danger of explosion

Product does not present an explosion hazard.

• Explosion limits

 

Lower

1.1 Vol %

Upper

10.6 Vol %

• Vapour pressure at 20°C

23 hPa

• Density at 20°C

1.01 g/cm³

• Solubility in / Miscibility with

 

water

Fully miscible.

• pH-value at 20°C

> 7

Heading10 - West India Chemical

Thermal decomposition / conditions to be avoided

No decomposition if used according to specifications.-

Dangerous reactions No dangerous reactions known.

Dangerous decomposition products

Carbon monoxide and carbon dioxide.

Heading11 - West India Chemical

Acute toxicity

Primary irritant effect:

on the skin

No irritant effect.

on the eye

No irritating effect.

Sensitization

No sensitizing effects known.

Additional toxicological information

The product shows the following dangers according to the calculation method of the General EU

Classification Guidelines for Preparations as issued in the latest version

Harmful

Heading12 - West India Chemical

General notes

Water hazard class 2 (German Regulation) (Self-assessment): hazardous for water.Do not allow product to reach ground water, water course or sewage system..Danger to drinking water if even small quantities leak into the ground.

Heading13 - West India Chemical

Product Recommendation

Must not be disposed together with household garbage. Do not allow product to reach sewage system.

Uncleaned packaging Recommendation

Disposal must be made according to official regulations.

Recommended cleansing agents

Water, if necessary together with cleansing agents.

Heading14 - West India Chemical

• Land transport ADR/RID (cross-border) • ADR/RID class : - • Maritime transport IMDG: • IMDG Class : - • Marine pollutant  : No • Air transport ICAO -TI and IATA-DGR : • ICAO/IATA Class : -

Heading15 - West India Chemical

Labelling according to EU guidelines

The product has been classified and marked in accordance with EU Directives / Ordinance on Hazardous Materials.

Code letter and hazard designation of product

Xn Harmful

Risk phrases

22 Harmful if swallowed.

Safety phrases

23 Do not breathe gas/fumes/vapour/spray (appropriate wording to be specified by the manufacturer). 26 In case of contact with eyes, rinse immediately with plenty of water and seek medical advice. 36/37/39 Wear suitable protective clothing, gloves and eye/face protection. 60 This material and its container must be disposed of as hazardous waste.

National regulations

Waterhazard class

Water hazard class 2 (Self-assessment): hazardous for water.

Heading16 - West India Chemical

This information is based on our present knowledge. However, this shall not constitute a guarantee for any specific product features and shall not establish a legally valid contractual relationship. • Relevant R-phrases. 20/21/22 Harmful by inhalation, in contact with skin and if swallowed..22 .Harmful if swallowed. 36/38     Irritating to eyes and skin. 41 Risk of serious damage to eyes.

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

  

Supply Locations

RXSOL HCF Remover | Hydrocarbon-Free Marine Tank Cleaning Chemical Manufacturer

RXSOL HCF Remover is a powerful low-foaming marine tank cleaning chemical for removing hydrocarbon residues, animal oils, vegetable oils, grease and sludge. Supplier in India, UAE and Oman.

Tank Cleaning Chemical Manufacturer and supplier in Mumbai, Kandla, Mundra, Kolkata, Chennai, Visakhapatnam, Fujairah, Dubai, Sharjah, Abu Dhabi, Muscat and Sohar.

HCF Remover is a cleaning chemical, not a guarantee that a tank is hydrocarbon-free or gas-free. Tank acceptance requires appropriate inspection and testing. Follow the current SDS, coating compatibility requirements, enclosed-space entry procedures and applicable wash-water disposal regulations.

HCF Cleaner manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of HCF Cleaner at a competitive price from us. We have ready stock of HCF Cleaner in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.

Need pricing or a bulk quote?

Send us the product and quantity — our Gandhidham team replies with a quote the same day.

Request a Quote