Skip to main content
Home / Products / Air Lines-36 / Turbine Wash Antifreeze GT

Turbine Wash Antifreeze GT

Turbine Wash Antifreeze GT
Air Lines-36
Product code  RXSOL-36-1586-220

High purity glycol additive with inhibitors used in gas turbine compressor washing and rinsing fluids to help prevent freezing under low temperature operating conditions

Supply to Kandla, Mundra & Sikka ports Bulk & custom packaging Technical support included

Product Description

RXSOL Gas Turbine Compressor Wash Antifreeze is a glycol-based antifreeze additive designed for use in gas turbine compressor washing and rinsing fluids under low-temperature operating conditions. It helps prevent freezing of the cleaning solution during compressor washing and rinsing operations when ambient temperatures fall below the normal operating range.

The product is based on technical-grade glycols, selected for low volatility and relatively low toxicity compared with many alternative glycol-based antifreeze agents. It is intended to be added to the compressor wash solution in accordance with the recommendations of the gas turbine Original Equipment Manufacturer (OEM).

Application & Usage

Antifreeze for gas turbine compressor washing manufactured and supplied as a concentrate for dilution at site. Get cost effective Antifreeze for gas turbine compressor washing liquid and mix it as per dilution given below with RXSOL Gas Turbine Cleaner GTC 1000 or RXSOL 27 Gas Turbine Cleaner.

Dosage

Complete dilution and mixing chart is given for RXSOL Antifreeze for gas turbine compressor washing liquid: RXSOL Turbine Wash Antifreeze GT

Technical Specifications

Property

Typical Specification

Appearance

Clear, colourless liquid

Odour

Practically odourless to faint characteristic odour

Solubility in Water

Completely miscible

Relative Density at 20°C

Approximately 1.036-1.040

Boiling Point

Approximately 188°C

Flash Point

Approximately 99-120°C, depending on test method

Vapour Pressure

Low at ambient temperature

Remarks / Precautions

Key Features of RXSOL Turbine Wash Antifreeze GT
  • Freeze Protection: Helps reduce the risk of freezing in compressor washing and rinsing fluids at low ambient temperatures.
  • Low Volatility: RXSOL Turbine Wash Antifreeze has a relatively low vapour pressure under normal operating conditions.
  • Water Miscibility: Mixes readily with water to facilitate preparation of compressor washing solutions.
  • Controlled Dilution: Allows the antifreeze concentration to be adjusted according to ambient temperature and applicable OEM recommendations.
  • Versatile Application: Suitable for incorporation into compatible aqueous compressor cleaning and rinsing solutions.

Procedure

Complete dilution and mixing chart is given for RXSOL Antifreeze for gas turbine compressor washing liquid: RXSOL Turbine Wash Antifreeze GT

Notes

How to use RXSOL Gas Turbine Compressor Washing Antifreeze along with RXSOL GTC 1000 / RXSOL 27 Gas Turbine Cleaner?

The product is intended for use as an antifreeze additive in aqueous cleaning and rinsing fluids used during gas turbine compressor washing.

It may be used where low ambient temperatures create a risk of freezing during the washing, rinsing, or associated operating procedures.

The required concentration depends on the ambient temperature, the composition of the cleaning solution, and the specific requirements of the gas turbine manufacturer.

Important: Always follow the gas turbine OEM's instructions regarding antifreeze selection, concentration, compatibility, and compressor washing procedures. Do not assume that the recommended mixture is suitable for every turbine model or cleaning formulation.

Recommended Dilution for Gas Turbine Compressor Washing

The following table provides the recommended dilution of RXSOL GTC 1000 / RXSOL 27 Gas Turbine Cleaner concentrate and water/RXSOL Turbine Wash Antifreeze GT for a total prepared mixture of 100 litres.

Outside Air Temperature

RXSOL GTC 1000 / RXSOL 27 Concentrate (L)

Water (L)

MPG (L)

Total (L)

Above +5°C

20

80

0

100

+5°C to −5°C

20

60

20

100

−5°C to −20°C

20

40

40

100

−20°C to −30°C

20

30

50

100

−30°C to −40°C

20

20

60

100

Other Names

Antifreeze for Gas Turbine Compressor Washing

Packing Sizes

Gas Turbin Wash Antifreeze is available in 25 Kg cans, 220 kg drums, 1200 Kg tanks.

Material Safety Data Sheet (MSDS)

Heading1 - West India Chemical

Product Code RXSOL-36-1586-220
Product Name Turbine Wash Antifreeze GT

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Stock Point : Mumbai, Kandla, Chennai, Visakhapatnam, Kolkata, Fujairah, Muscat, Canada, Nairobi

Phone +91 22 65113333 / 5555 / 9999 / 27815540/41
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email mail @ rxmarine.com

Heading2 - West India Chemical

Chemical Name

CAS Number

EC Number

Propane-1,2-diol

57-55-6

200-338-0

Proprietory blend of corrosion inhibitors - -

Heading3 - West India Chemical

Hazard description: Not applicable.
Information concerning particular hazards for human and environment: Not applicable.

Heading4 - West India Chemical

General information No special measures required.

After inhalation

Supply fresh air; consult doctor in case of complaints.

After skin contact

Generally the product does not irritate the skin.

After eye contact

Rinse opened eye for several minutes under running water.

After swallowing

If symptoms persist consult doctor.

Heading5 - West India Chemical

Suitable extinguishing agents: Use fire extinguishing methods suitable to surrounding conditions.
Protective equipment: No special measures required.

Heading6 - West India Chemical

6.1 Personal Precautions, Protective Equipment and Emergency Procedures

No special personal safety precautions are normally required for small quantities under normal conditions of use. Avoid unnecessary contact with the spilled product and use appropriate personal protective equipment where prolonged contact or large-scale spills are involved.

6.2 Environmental Precautions

Dilute with plenty of water where appropriate and safe to do so. Do not allow the undiluted product or large quantities of the material to enter sewers, surface water or ground water. Prevent uncontrolled release into the environment.

6.3 Methods and Material for Containment and Cleaning Up

Contain the spill and collect the material using suitable liquid-binding/absorbent materials, such as:

  • Sand

  • Diatomite

  • Acid binders

  • Universal binders

  • Sawdust

Collect the absorbed material into suitable, properly labelled containers for appropriate disposal in accordance with applicable local regulations. Clean the affected area with water after removal of the spilled material, while preventing contaminated wash water from entering drains or watercourses.

6.4 Additional Information

Under normal conditions of use and handling, no dangerous substances are released. Avoid uncontrolled discharge of concentrated product into drains or natural water systems.

Heading7 - West India Chemical

Handling:
 Information for safe handling:
 Handling:
 Information for safe handling: No special requirement
 Information about fire - and explosion protection: No special measures required.
Storage:
 Requirements to be met by storerooms and receptacles: No special requirements.
 Information about storage in one common storage facility: Not required.
 Further information about storage conditions: None.
 Information about fire - and explosion protection: No special measures required.
Storage:
 Requirements to be met by storerooms and receptacles: No special requirements.
 Information about storage in one common storage facility: Not required.
 Further information about storage conditions: None.

Heading8 - West India Chemical

Additional information about design of technical facilities: No further data; see item 7.

Ingredients with limit values that require monitoring at the workplace:
57-55-6 propane-1,2-diol
WEEL (USA)
WEL (Great Britain)
10 mg/m³
474* 10** mg/m³, 150* ppm
*total vapour and particulates **particulates

Additional information: The lists valid during the making were used as basis.
Personal protective equipment:
General protective and hygienic measures:
The usual precautionary measures are to be adhered to when handling chemicals.
Respiratory protection: Not required.
Protection of hands: The glove material has to be impermeable and resistant to the product/ the substance/ the preparation. Due to missing tests no recommendation to the glove material can be given for the product/ the preparation/ the chemical mixture. Selection of the glove material on consideration of the penetration times, rates of diffusion and the degradation
Material of gloves:The selection of the suitable gloves does not only depend on the material, but also on further marks of quality and
varies from manufacturer to manufacturer.

Penetration time of glove material:The exact break through time has to be found out by the manufacturer of the protective gloves and has to be   observed.
Eye protection: Goggles recommended during refilling.

Heading9 - West India Chemical

General Information

Form

Fluid

Colour

Colourless

Odour

Nearly Odourless

Change in condition

Melting point/Melting range

-68°C

Boiling point/Boiling range

185°C

Flash point

> 100°C

Ignition temperature

371°C

Danger of explosion Product does not present an explosion hazard.
Explosion limits  
Lower 2.6 Vol %
Upper 12.6 Vol %
Vapour pressure at 20°C 0.11 hPa
Density at 20°C 1.0362 g/cm³
Solubility in / Miscibility with water Fully miscible.
pH-value (- g/l) neutral
Viscosity
Dynamic at 25°C 46 mPas

Heading10 - West India Chemical

Thermal decomposition / conditions to be avoided: No decomposition if used according to specifications.
Dangerous reactions No dangerous reactions known.
Dangerous decomposition products: No dangerous decomposition products known.

Heading11 - West India Chemical

Acute toxicity:
LD/LC50 values relevant for classification:  

Oral

Dermal

LD50

LD50

2000 mg/kg (rat)

20800 mg/kg (rabbit)

Primary irritant effect:
on the skin No irritant effect.
on the eye No irritating effect.
Sensitization No sensitizing effects known.
Additional toxicological information:
When used and handled according to specifications, the product does not have any harmful effects to our experience and the information provided to us.
The substance is not subject to classification according to the latest version of the EU lists.

Heading12 - West India Chemical

General notes: Water hazard class 1 (German Regulation) (Assessment by list): slightly hazardous for water Do not allow undiluted product or large quantities of it to reach ground water, water course or sewage system.

Heading13 - West India Chemical

Product:
Recommendation Smaller quantities can be disposed of with household waste.
Uncleaned packaging:
Recommendation: Disposal must be made according to official regulations.
Recommended cleansing agents: Water, if necessary together with cleansing agents.

Heading14 - West India Chemical

Land transport ADR/RID (cross-border)
ADR/RID class: -
Maritime transport IMDG:
IMDG Class: -
Marine pollutant: No
Air transport ICAO-TI and IATA-DGR:
ICAO/IATA Class: -

Heading15 - West India Chemical

Labelling according to EU guidelines:
Observe the general safety regulations when handling chemicals.
The substance is not subject to classification according to EU lists and other sources of literature known to us.

Heading16 - West India Chemical

This information is based on our present knowledge.However, this shall not constitute a guarantee for anys pecific product features and shall not establish a legally valid contractual relationship.

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Supply Locations

Antifreeze for gas turbine compressor washing exporter and supplier in Mumbai, Chennai, Kolkata, Visakhapatnam, Gandhidham, Fujairah, Dubai, Ajman, Sharjah Abudhabi, Muscat Barka Ruwi Sohar, Oman, Canada, Sudan, Yemen, Michigan USA

#AntifreezeGasTurbineCompressorWashingUAE
#AntifreezeGasTurbineCompressorWashingOMAN
#AntifreezeGasTurbineCompressorWashingINDIA

Need pricing or a bulk quote?

Send us the product and quantity — our Gandhidham team replies with a quote the same day.

Request a Quote