Rust Remover
RXSOL-22-1088-001Excellent pre treatment and binder for metal surfaces to be painted. Concentrated blend of RXSOL proprietory formulated various products, which is specifically designed for the rapid removal of rust, while providing phosphatized ferrous metal surfac
Product Description
RXSOL Rust Remover
Product Description
RXSOL Rust Remover is a concentrated, acid-based cleaning and descaling compound formulated for the effective removal of rust, iron oxide, corrosion deposits, mineral scale and oxidation from ferrous metal surfaces.
The product penetrates and reacts with rust deposits, helping loosen and dissolve iron oxides so that contaminated surfaces can be cleaned with less mechanical effort. It is particularly suitable for marine, shipboard, shipyard, workshop and industrial maintenance where rusted steel components require cleaning or surface preparation.
RXSOL Rust Remover can be used on steel structures, machinery, pipelines, tanks, tools, fabricated components and other compatible acid-resistant surfaces. After treatment, surfaces should be thoroughly rinsed with fresh water and, where required, neutralized and protected against flash rusting.
Rust Remover manufacturer, supplier and exporter. Rust remover is advanced blend of various acid with additional base and inhibitor. Its powerful chemical rust removal action dissolves rust without any mechanical action. This is the reason why Rust Remover is so popular for removal of rust before painting.
Easy Rust Removing solution manufactured by RXSOL. Best Rust Remover liquid.
Application & Usage
RXSOL Rust Remover is recommended for cleaning rust and corrosion from:
- Ship decks and steel structures
- Marine equipment and machinery
- Engine-room components
- Steel pipes and pipelines
- Tanks and fabricated steel sections
- Nuts, bolts, tools and mechanical components
- Workshop equipment
- Heat-transfer equipment where compatible
- Rusted steel prior to painting or coating
- Industrial plant and maintenance equipment
Very effective products to removes rust and stains also improves metal appearance.
Direction for use
For rust removal the surfaces to be treated should be free form loose materials, flaking paint, dirt or oil. In most cases diluted solution of RXSOL-16-1088-025 , can be applied by brush ranging from 10-50% and left to react for 5 - 40 minutes then the residues should be rinsed off thoroughly with clean water jet . Smaller objects can be soaked in plastic container. After cleaning, rinse items thoroughly with a water jet.
• For aluminium , only diluted solution up to 10 - 25% can be used and rinse with in 10- 30mins.
• For stainless Steel Disc Cleaning (never use on copper, brass or bronze parts), dilute to 4 - 10 parts water, and immerse from 1 - 3 hours depending on the severity of the job concerned. Cleaning will be accelerated with elevate4d temperatures up to 60°C and agitaion. After cleaning rinse thoroughly with clean water.
For best performance on aluminium use RXSOL Degreaser for degreasing as it has a neutral pH. Paintwork :
RXSOL-16-1011-RR should be diluted with water 1:4 . Then solution can be applied by brushing, spraying for 10 - 20 minutes the residues should be rinsed off thoroughly with high pressure water.
Dosage
Recommended Dilution & Application
For heavy rust and severe corrosion deposits, RXSOL Rust Remover may be used neat or at high concentration, subject to the substrate and the approved product formulation.
For medium rust, a typical starting dilution of 1 part product with 1–3 parts water may be used.
For light rust, oxidation and routine maintenance, dilution may be increased to approximately 1:5 to 1:10 with water.
Apply the prepared solution uniformly to the rusted area using a suitable acid-resistant brush, spray equipment or immersion tank. Allow sufficient contact time for the rust to soften and dissolve. Agitation or brushing can accelerate removal of stubborn deposits.
Do not allow the product to dry on the surface. After cleaning, rinse thoroughly with fresh water.
For steel surfaces that will not immediately be painted or coated, an appropriate neutralization/passivation or temporary corrosion-protection treatment is recommended to minimize flash rusting.
Immersion Cleaning
Small rusted components such as tools, bolts, fittings and mechanical parts may be immersed in a suitably diluted solution.
Typical procedure:
- Remove loose dirt, oil and grease before treatment.
- Prepare the required RXSOL Rust Remover solution.
- Immerse the component and periodically inspect the surface.
- Remove when the required degree of rust removal has been achieved.
- Rinse thoroughly with fresh water.
- Neutralize where required.
- Dry promptly and apply corrosion protection if the component is not immediately coated.
On completion of degreasing CLEANING OPERATION if rust / scale ( water ) stains from metal surface ,use 10 to 50% of RXSOL-16-1088-025 with fresh water for 20 -30 minutes.
Appearance : Clear & Colourless fLiquid
Specific gravity (200C) : 1.21
Flash point cc : None
Note : Also can be used for Disc cleaning without dismantling Disc Stacks
: Improves efficiency of centrifuge installation.
Useful Area
Important Material Compatibility
RXSOL Rust Remover is intended primarily for compatible ferrous metal surfaces. Acidic rust removers can attack sensitive materials.
Avoid uncontrolled application on aluminium, zinc, galvanized steel, magnesium, marble, limestone and other acid-sensitive surfaces. Compatibility with stainless steel and non-ferrous alloys depends on the specific acid chemistry, concentration, temperature and exposure time.
A small compatibility test should be carried out before treating an unfamiliar substrate.
Handling & Safety
RXSOL Rust Remover is an acidic chemical product. Appropriate chemical-resistant gloves, protective clothing and eye/face protection should be used during handling.
Always add the product to water when preparing dilutions, unless the approved product instructions specify otherwise. Avoid contact with skin and eyes and avoid inhalation of spray mist.
Do not mix with chlorine-releasing chemicals, hypochlorites, alkaline cleaners or incompatible chemicals.
Refer to the current RXSOL Safety Data Sheet (SDS/MSDS) before use.
Storage
Store in the original, tightly closed, acid-resistant container in a cool, dry and well-ventilated area, protected from direct sunlight and excessive heat. Keep separated from alkalis, oxidizing agents, chlorine products and incompatible materials.
#RustREMOVER_Mumbai
#RustREMOVER_Dubai
#RustREMOVER_Chennai
#RustREMOVER_Kolkata
#RustREMOVER_Visakhapatnam
#RustREMOVER_Muscat
#RustREMOVER_Nairobi
Technical Specifications
Typical Specifications
| Property | Typical Specification |
|---|---|
| Product Name | RXSOL Rust Remover |
| Product Type | Acid-based rust and scale remover |
| Appearance | Clear to slightly hazy liquid |
| Colour | Colourless to pale coloured* |
| Odour | Characteristic acidic odour |
| pH | Strongly acidic, typically 2 |
| Specific Gravity @ 25°C | Typically 1.10–1.25* |
| Solubility in Water | Completely miscible |
| Active Function | Rust / iron oxide dissolution |
| Foam | Low to moderate |
| Application | Brush, spray, immersion or circulation |
| Dilution | Neat or diluted depending on rust severity |
| Rinsability | Excellent with fresh water |
| Principal Use | Rust, corrosion and scale removal |
Exact values should be confirmed against the final RXSOL formulation and batch COA.
Remarks / Precautions
Key Features of Rust Remover RXSOL
- Effective removal of rust and iron oxide deposits
- Helps remove corrosion scale and mineral deposits
- Concentrated liquid formulation
- Penetrates heavily rusted surfaces
- Reduces extensive mechanical scraping and wire brushing
- Suitable for marine and industrial maintenance
- Can be applied by brushing, spraying, soaking or circulation, depending on the equipment and application
- Useful for surface preparation before painting or protective treatment
- Water-rinsable after cleaning
- Suitable for controlled dilution according to the degree of contamination
This is a well balanced blend of corrosion inhibitors , and surface active highly emulsified acidic materials product for the cleaning of aluminium, copper and removal of rust stains on paint work.
Do not eat, drink or smoke while handling it; wash carefully with soap and water before meals and after work shift as shower is recommended.
R 34 : Causes burns.
S 26 : On contact with eyes,Wash eye ball immediately with plenty of water and seek medical advice.
Procedure
Recommended Dilution & Application
For heavy rust and severe corrosion deposits, RXSOL Rust Remover may be used neat or at high concentration, subject to the substrate and the approved product formulation.
For medium rust, a typical starting dilution of 1 part product with 1–3 parts water may be used.
For light rust, oxidation and routine maintenance, dilution may be increased to approximately 1:5 to 1:10 with water.
Apply the prepared solution uniformly to the rusted area using a suitable acid-resistant brush, spray equipment or immersion tank. Allow sufficient contact time for the rust to soften and dissolve. Agitation or brushing can accelerate removal of stubborn deposits.
Do not allow the product to dry on the surface. After cleaning, rinse thoroughly with fresh water.
For steel surfaces that will not immediately be painted or coated, an appropriate neutralization/passivation or temporary corrosion-protection treatment is recommended to minimize flash rusting.
Immersion Cleaning
Small rusted components such as tools, bolts, fittings and mechanical parts may be immersed in a suitably diluted solution.
Typical procedure:
- Remove loose dirt, oil and grease before treatment.
- Prepare the required RXSOL Rust Remover solution.
- Immerse the component and periodically inspect the surface.
- Remove when the required degree of rust removal has been achieved.
- Rinse thoroughly with fresh water.
- Neutralize where required.
- Dry promptly and apply corrosion protection if the component is not immediately coated.
On completion of degreasing CLEANING OPERATION if rust / scale ( water ) stains from metal surface ,use 10 to 50% of RXSOL-16-1088-025 with fresh water for 20 -30 minutes.
Appearance : Clear & Colourless fLiquid
Specific gravity (200C) : 1.21
Flash point cc : None
Note : Also can be used for Disc cleaning without dismantling Disc Stacks
: Improves efficiency of centrifuge installation.
Material Safety Data Sheet (MSDS)

| Product Name | Rust Remover |
| Part Number | RXSOL-22-1088-001 |
Company Details:....
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Branch : Kandla, Mumbai , Chennai, Vizag, Kolkata, UAE , OMAN , CANADA and KENYA
| Phone | +91 22 20871200 - 1400 |
| Fax | +91 22 27612100 :::AOH :0091 9821214367 |
| mail @ rxmarine.com | |
| Website | www.rxmraine.com |

| Ingredient | CAS # | Weight Percent | US Hazcom 2012/ GHS Classification |
|
Water and Non Hazardous
Ingredients
|
Mixture | 100 | Not Hazardous |

| Hazcom 2012/GHS Classification | Not classified as Hazardous |
| Label Elements | None Required |

| Ingestion (Swallowed) | Rinse out mouth and give sips of water. Do not induce vomiting. Get medical attention. Call physician, poison control center or the WD-40 Safety Hotline at 1-888-324-7596. |
| Eye Contact | Flush thoroughly with water then remove contact lenses if present, and easy to do so. Continue flushing eyes for several minutes. Get medical attention if irritation persists |
| Skin Contact | Flush thoroughly with water. Remove any contaminated clothing and launder before reuse. If irritation develops and persists, get medical attention |
| Inhalation (Breathing) | Discontinue use and move to fresh air. Get medical attention if irritation develops and persists. |
| Signs and Symptoms of Exposure | May cause mild skin irritation on prolonged contact |
| Indication of Immediate Medical Attention/Special Treatment Needed | Immediate medical attention is not required. |

| Suitable (and unsuitable) Extinguishing Media | This product is not flammable or combustible. Use any media that is appropriate for the surrounding fire. |
| Specific Hazards Arising from the Chemical |
Highly flammable liquid and vapor. Runoff to sewer may create fire or explosion hazard.
In a fire or if heated, a pressure increase will occur and the container may burst, with the
risk of a subsequent explosion. The vapor/gas is heavier than air and will spread along
the ground. Vapors may accumulate in low or confined areas or travel a considerable
distance to a source of ignition and flash back.
Highly flammable liquid and vapor. Runoff to sewer may create fire or explosion hazard.
In a fire or if heated, a pressure increase will occur and the container may burst, with the
risk of a subsequent explosion. The vapor/gas is heavier than air and will spread along
the ground. Vapors may accumulate in low or confined areas or travel a considerable
distance to a source of ignition and flash back.
Highly flammable liquid and vapor. Runoff to sewer may create fire or explosion hazard.
In a fire or if heated, a pressure increase will occur and the container may burst, with the
risk of a subsequent explosion. The vapor/gas is heavier than air and will spread along
the ground. Vapors may accumulate in low or confined areas or travel a considerable
distance to a source of ignition and flash back.
Thermal decomposition will release oxides of carbon, and oxides of phosphorous.
|
| Special Protective Equipment and Precautions for Fire-Fighters |
Firefighters should always wear positive pressure self-contained breathing apparatus and full protective clothing for fires involving chemicals. |

| Personal Precautions, Protective Equipment and Emergency Procedures | Wear appropriate protective clothing (see Section 8). |
| Methods and Materials for Containment/Cleanup | Spills can be collected with an absorbent material and placed in a container for disposal. Clean the spill area with water. Large spills should be contained with an inert absorbent material. Collect into containers for proper disposal. |

Precautions for safe handling
| Precautions for Safe Handling | Avoid eye contact. Avoid prolonged or repeated contact with skin. Keep container closed when not in use. Wash thoroughly after use. Keep out of the reach of children. |
| Conditions for Safe Storage | Store in a cool, dry area. Avoid freezing. |

| Chemical | Occupational Exposure Limits |
| Non-Hazardous Ingredients | None Established |
The Following Controls are Recommended for Normal Consumer Use of this Product
| Appropriate Engineering Controls | Use in a well-ventilated area. |
| Personal Protection | |
| Eye Protection | Avoid eye contact. |
| Skin Protection | Avoid prolonged skin contact. For sensitive skin or prolonged use, wear rubber gloves. |
| Respiratory Protection | None required. |
| For Bulk Processing or Workplace Use the Following Controls are Recommended | |
| Engineering Controls | Use with adequate general ventilation or local exhaust to minimize exposure levels. |
| Personal Protection | |
| Eye Protection | Follow facility requirements |
| Skin Protection | Wear rubber gloves and protective clothing as required to avoid prolonged skin contact. |
| Respiratory Protection | No respiratory protection normally required. If exposure levels are excessive, wear an approved respirator. Selection of respiratory protection depends on the contaminant type, form and concentration. Select in accordance with OSHA 1910.134 and good Industrial Hygiene practice. |
| Work/Hygiene Practices | Avoid contact with the eyes, skin and clothing. Wash thoroughly after use. |

| Appearance | Clear, colorless Liquid |
| Odor | Slight |
| Odor Threshold | Not established |
| pH | 6-8 |
| Melting/freezing point | Not established |
| Boiling point/Range | Not determined |
| Flash Point | None |
| Evaporation Rate | Same as water |
| Flammability (solid, gas) | Not applicable |
| VOC | 0.0 lb/gal |
| Flammable Limits (Solvent Portion) | Not applicable |
| Vapor Pressure | Same as water |
| Vapor Density | Same as water |
| Relative Density | 1.05 |
| Solubilities | Soluble in water |
| Partition Coefficient; noctanol/water | Not established |
| Autoignition Temperature | None |
| Decomposition Temperature | Not established |
| Viscosity | Not established |
| Pour Point | Not applicable |

| Reactivity | Not reactive |
| Chemical stability | Stable |
| Possibility of hazardous reactions | None known. |
| Conditions to avoid | Avoid freezing and extreme temperatures. |
| Incompatible materials |
Strong acids.
|
| Hazardous decomposition products | Thermal decomposition will release oxides of carbon, and oxides of phosphorous. |

Symptoms of Overexposure
| Inhalation | No adverse effects expected under normal conditions. Mists may cause irritation, mucous membranes of the throat and nose and upper respiratory tract. |
| Skin Contact | May cause mild irritation on prolonged or repeated contact. |
| Eye Contact | No significant eye irritation is expected. Direct contact may cause mild, transient discomfort. |
| Ingestion | May cause irritation to the mouth and gastrointestinal tract. |
| Chronic Effects | None currently known. |
| Carcinogen Status |
None of the components are listed as a carcinogen or suspect carcinogen by IARC, NTP, ACGIH or OSHA.
|
| Reproductive Toxicity | None of the components is considered a reproductive hazard. |
| Numerical Measures of Toxicity | No data available |
| Acute Toxicity Estimates: Oral >5000 mg/kg, Dermal >2000 mg/kg. Based on a review of the components, this product is not acutely toxic. Non-irritant in in-vitro eye study and mild irritant in in-vitro skin irritation studies. |

| Ecotoxicity | No specific data for the product is available. Avoid release to the environment. |
| Persistence and Degradability | No data available. |
| Bioaccumulative Potential | No data available. |
| Mobility in Soil | No data available. |
| Other Adverse Effects | None known |

| Dispose in accordance with local, state and federal regulations. Consider contamination that may have occurred during rust removal process when determining disposal method. |

| Not Regulated for transportation. |

| U.S. Federal Regulations | |
| CERCLA 103 Reportable Quantity | This product is not subject to CERCLA reporting requirements. Many states have more stringent release reporting requirements. Report spills required under federal, state and local regulations. |
| SARA TITLE III | |
| Hazard Category For Section 311/312 | Not Hazardous |
| Section 313 Toxic Chemicals | This product contains the following chemicals subject to SARA Title III Section 313 Reporting requirements: None |
| Section 302 Extremely Hazardous Substances (TPQ) | None |
| EPA Toxic Substances Control Act (TSCA) Status | All of the components of this product are listed on the TSCA inventory. |
| California Safe Drinking Water and Toxic Enforcement Act (Proposition 65) | This product does not require a California Proposition 65 warning. |
| Canadian Environmental Protection Act | All of the ingredients are listed on the Canadian Domestic Substances List or exempt from notification |
| Canadian WHMIS Classification | Not a controlled product. |
| This MSDS has been prepared according to the criteria of the Controlled Products Regulation (CPR) and the MSDS contains all of the information required by the CPR. |

| Other Information |
The information above is believed to be accurate and represents the best information currently available to us. However, we make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and weassume no liability resulting from its use. Users should make their own investigations to determine the suitability of the information for their particular purposes. In no event shall be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if Rx Marine International has been advised of the possibility of such damages. DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable. |